Products

Server


Intel® Server Chassis SC5400Specifications

  • Overview
  • Specifications
  • Support

Product specifications

Form factor Pedestal or 5U rack (requires rack conversion kit ARIGRACK)
Server board support Base

Intel® Server Board S5000PSL
Intel® Server Board S5000XVN

BRP, LX, LXI

Intel® Server Board S5000PSL
Drive bays Base

One tool-less fixed drive bay for up to six fixed drives
Optional hot-swap / tool-less drive bays available:
  • 6-drive SAS/SATA
  • 6-drive SCSI

BRP, LX

One tool-less fixed drive bay for up to six fixed drives
Optional hot-swap / tool-less drive bays available:
  • 6-drive SAS/SATA, 4-drive SAS/SATA
  • 6-drive SCSI, 4-drive SCSI
  • Optional 4-drive tool-less fixed drive bay

LXI

Includes: One hot-swap 6-drive SAS/SATA drive bay (product code AXX6DRV3G). Optional support for 4-drive SAS/SATA drive bay (AXX4DRV3G or AXX4DRV3GEXP).
Hot-swap disk drive bay: order code Base
Up to six hot-swap drive bays via the following hot-swap disk drive bay upgrade kits:
  • 6-drive SCSI – AXX6SCSIDB
  • 6-drive SAS/SATA – AXX6DRV3G
  • 6-drive SAS/SATA Expander – AXX6DRV3GEXP

BRP, LX
Up to ten hot-swap drive bays are possible with the combination of the following drive bay upgrade kits:
  • 6-drive SCSI – AXX6SCSIDB
  • 6-drive SAS/SATA – AXX6DRV3G
  • 6-drive SAS/SATA Expander – AXX6DRV3GEXP
  • 4-drive SCSI – AXX4SCSIDB
  • 4-drive SAS/SATA – AXX4DRV3G
  • 4-drive SAS/SATA Expander – AXX4DRV3GEXP

LXI
Up to ten hot-swap drives are possible with the combination of the following, optional, drive bay upgrade kits:
  • 4-drive SAS/SATA – AXX4DRV3G
  • 4-drive SAS/SATA Expander – AXX4DRV3GEXP
Power supply Base

670-watt PFC

BRP, LX, LXI

830-watt, dual-line cord, 1+1 PFC
Hot-swap, redundant power capable Base

Via upgrade kit

BRP, LX

Fully redundant configuration (requires optional second power module FXX830WPSU)

LXI

Fully redundant configuration (ships with two power supply modules FXX830WPSU)
Hot-swap, redundant fans Base

2 non-redundant fans. Hot-swap redundant fans not available.

BRP

2 non-redundant fans. Hot-swap, redundant fans available via upgrade kit (ARIG2HSFANKIT).

LX, LXI

Fully redundant configuration (ships with 4 hot-swap fans)