Server Products
Intel® RAID Controller RS2BL040
Controller LED and connector information

The following figure shows the jumpers and connectors on Intel® RAID Controller RS2BL040. A description for each jumper and connector is provided in the table that follows the figure.

Jumper

Description

Type

Comments

JT1

Dirty Cache LED Header

2-pin connector

For connection to enclosure LED. When lit, it indicates the data in the cache has not been written to disk.

JT2

Drive Activity LED Header

2-pin connector

LED signal for drive activity.

JT3

Board-to-board connector for Battery Backup Unit

20-pin connector

Provides an interface to the daughter card that contains the battery backup unit.

JT4

Drive Fault LED Header

2-pin connector

LED signal for any drive fault.

JT6

Internal SAS/SATA Port Connector, Ports 0-3

SFF8087

Connection to SAS/SATA devices.

JT8

Debug Connector

2-pin connector

Reserved.

JT9

Set Factory Defaults Connector

2-pin connector

Resets the board settings to the defaults set in the factory.

JT10

Debug Connector

2-pin connector

Reserved

JT11

Keyed I2C Connector

3-pin keyed connector

Out-of-band enclosure management (SES2)

The Intel® RAID Controller RS2BL040 contains the following LEDs:

One surface-mounted heartbeat (“CRT1”) LED (Green Color) to indicate SAS2108 activity.

Another surface-mounted system error (“CRT2”) LED (Red Color) to indicate a board error.

Additional LED signaling is available through stake pin connectors on the controller.

This applies to:
Intel® RAID Controller RS2BL040

Solution ID: CS-030794
Date Created: 17-Aug-2009
Last Modified: 12-Nov-2009
Back to Top