When the Intel® One Boot Flash Update (Intel® OFU) is used to update the BIOS or firmware, the update may not occur until the next reboot.
Refer to the table below for current Intel® Server Boards
| Firmware Component |
S7000FC4UR |
S3000AH, S3000PT |
S3200SH, X38ML |
S5400SF |
S5000PSL,S5000PAL, S5000XSL,S5000XAL, S5000XVN,S5000VCL |
| BIOS |
Next Reboot |
Immediately |
Immediately |
Next Reboot |
Next Reboot |
| BMC |
Next Reboot |
Not Supported |
Immediately |
Next Reboot |
Next Reboot |
| SDR |
Next Reboot |
Not Supported |
Immediately |
Next Reboot |
Next Reboot |
| FRU |
Immediately |
Not Supported |
Immediately |
Immediately |
Immediately |
| HSC |
Immediately |
Not Supported |
Not Supported |
Immediately |
Immediately |
| Local Control Panel (LCP) 1 |
Immediately |
Not Supported |
Not Supported |
Not Supported |
Immediately |
| Intel® Remote Management Module 1 1 |
Not Supported |
Not Supported |
Not Supported |
Not Supported |
Immediately |
| Intel® Remote Management Module 2 2 |
Not Supported |
Not Supported |
Not Supported |
Not Supported |
Not Supported | |
| Note |
When the firmware is contained in a single block, the new firmware will be active immediately upon update. When the firmware is contained in two blocks, the OFU will update the second block initially, and wait for the next reboot to update the first block. | |
1 HSC, LCP & RMM 1 - Some components are optional or configuration dependent and may not be present on all systems. HSC updates are not supported on expander HSC backplanes
2 Intel RMM2 firmware is updated using update utilities provided with the Intel RMM2 firmware updates
This applies to:
|