Server Products
Server Products
Newly added hard drive not recognized in operating system

Symptom(s):

When the onboard disk controller is configured as software RAID using Intel® Embedded Server RAID Technology II (ESRTII), and a new hard drive is connected to the server, the newly added hard drive is not recognized in the operating system.

Cause:

Intel® Embedded Server RAID Technology II does not support JBOD mode. To use a single standalone hard drive, create a RAID 0 virtual drive consist of the hard drive.

Solution:

Add a RAID 0 virtual drive consist of the newly added hard drive using the Intel® ESRTII BIOS Configuration Utility or Intel® RAID Web Console 2. For more details, please refer to the Intel® RAID software user's guide.

This applies to:
Intel® Server Board S1200BT
Intel® Server Board S3420GP
Intel® Server Board S5000PAL
Intel® Server Board S5000PSL
Intel® Server Board S5000VCL
Intel® Server Board S5000VSA
Intel® Server Board S5000XSL
Intel® Server Board S5400SF
Intel® Server Board S5500BC
Intel® Server Board S5500HCV
Intel® Server Board S5500HV
Intel® Server Board S5500WB
Intel® Server Board S5520HC
Intel® Server Board S5520UR
Intel® Server System SC5400RA
Intel® Server System SR1530CL
Intel® Server System SR1530HCL
Intel® Server System SR1530HCLS
Intel® Server System SR1560SF
Intel® Server System SR1600UR
Intel® Server System SR1625UR
Intel® Server System SR1630BC
Intel® Server System SR2520SA
Intel® Server System SR2600UR

Solution ID: CS-030492
Date Created: 17-May-2009
Last Modified: 07-Jun-2011
Back to Top